Ductless.ca, Inc. is an authorized Mitsubishi Mr. Slim dealer and has been serving the Toronto, Canada Area for over 25 years. Contact ductless.ca, Inc. for all of your ductless air conditioning and heating needs.
Mitsubishi Mr. Slim P-Series ductless air conditioners and heat pumps offer the attraction of being untraditional while providing efficiency and reliability for your commercial and industrial applications. Mitsubishi’s Mr. Slim P-Series are powerful enough for the toughest situations such as offices, server rooms, equipment rooms, restaurants, elevator rooms and retail locations.
With the latest technology available, Mitsubishi Mr. Slim ductless units will provide you decades of reliable cooling while paying for itself in just a few years from the energy savings alone!
For smaller residential and commercial applications, please see our M-Series page.
Mitsubishi M-Series Ductless Features
All Mitsubishi Mr. Slim ductless air conditioners sold through ductless.ca are authentic and not a grey market imports. All of our units are purchased from local distributors which in turn are supplied from Mitsubishi Electric Canada. You can take comfort in knowing that units purchased and installed by ductless.ca carry extended manufacturer warranties and support and are installed by factory trained professionals.
Mitsubishi P-Series ductless units are perfectly suited for the Canadian climate. Each unit comes standard with low-ambient cooling mode which allow the units to cool down to -18°C.
A special ultra low-ambient cooling option is also available for applications which require cooling when outside ambient temperatures dip down to -40°C (ultra-low ambient kit required).
Mitsubishi Electric’s exclusive patent-pending Hyper-Heat Inverter (H2i™) technology delivers heat even when outdoor temperatures drop to -25°C! Levels that are unmatched with the competitors. H2i technology delivers 100% heating capacity when temperatures drop
down to -15°C and 80% heating capacity at -25°C.
Most units have variable compressor speed inverter (VCSi) technology which adjusts the air conditioning capacity in response to demand. This allows Mitsubishi air conditioners to run more efficiently and reduce energy costs. By controlling the compressor rotation speed more precisely, VCSi technology provides high-speed cooling and heating with extra energy savings compared to conventional models.
Mitsubishi’s i-see Sensors see more then just room temperature. Equally important factors for feeling comfortable include radiant temperature, air movements, humidity and more. The i-see sensors measure radiant hot and cold spots within the room and focus airflow into those spots. This revolutionary system also controls the air movement and humidity levels, producing a much more comfortable environment than ever before (option on PLA and PCA units only).
The wall mounted slim smart remote control allows you to keep room comfort exactly where you want it and see the status of the entire system with just a glance such as temperature and airflow controls, enhanced service and maintenance functions, management security features and multiple systems control. Additionally, the display can be switched to one of eight different languages.
Mitsubishi has utilized R-410A which is a zero ozone depleting refrigerant since 2006 for all of their Mr. Slim ductless models in accordance with the Montreal Protocol.
PUZ Hyper Heat Series Heat Pumps
Model | PKA-A30KA | PKA-A36KA | PLA-A30BA | PLA-A36BA |
Rated Cooling Capacity | 30,000 Btu/h [2½ tons] |
33,500 Btu/h [2¾ tons] |
30,000 Btu/h [2½ tons] |
34,000 Btu/h [2¾ tons] |
Cooling Capacity (Min to Max) |
18,000 to 30,000 Btu/h |
18,000 to 34,200 Btu/h |
18,000 to 30,000 Btu/h |
18,000 to 36,000 Btu/h |
Rated Heating Capacity | 32,000 Btu/h [2¾ tons] |
38,000 Btu/h [3¼ tons] |
32,000 Btu/h [2¾ tons] |
38,000 Btu/h [3¼ tons] |
Heating Capacity (Min to Max) |
18,000 to 34,000 Btu/h |
18,000 to 40,000 Btu/h |
18,000 to 34,000 Btu/h |
18,000 to 40,000 Btu/h |
ENERGY STAR® Qualified Unit | Yes | |||
SEER | 16.5 | 16.2 | 15.6 | 17.0 |
HSPF | 9.5 | 10.0 | 9.4 | 10.0 |
Compressor Type | Inverter (VCSi and H²i) | |||
i-see Sensor | Not Available | Optional | ||
Indoor Unit Noise (Low-Medium-High-Powerful) |
39-42-45 dB | 43-46-49 dB | 28-30-32-34 dB | 32-34-37-40 dB |
Outdoor Unit Noise (Cooling/Heating) |
52/53 dB | |||
Cooling Power Consumption | 2,500 W | 2,790 W | 2,450 W | 2,690 W |
Heating Power Consumption | 2,930 W | 3,410 W | 3,440 W | 3,230 W |
Power Supply | 240v, Split-Phase, 60Hz | |||
Moisture Removal | 3.8 l/h | 4.1 l/h | 3.4 l/h | 3.3 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | |||
Outdoor Temperatures for Heating (Min to Max) |
-25 to 21 °C |
Model | PCA-A30KA | PCA-A36KA | PEAD-A30AA | PEAD-A36AA |
Rated Cooling Capacity | 30,000 Btu/h [2½ tons] |
34,000 Btu/h [2¾ tons] |
30,000 Btu/h [2½ tons] |
34,000 Btu/h [2¾ tons] |
Cooling Capacity (Min to Max) |
18,000 to 30,000 Btu/h |
18,000 to 36,000 Btu/h |
18,000 to 30,000 Btu/h |
18,000 to 36,000 Btu/h |
Rated Heating Capacity | 32,000 Btu/h [2¾ tons] |
38,000 Btu/h [3¼ tons] |
32,000 Btu/h [2¾ tons] |
38,000 Btu/h [3¼ tons] |
Heating Capacity (Min to Max) |
18,000 to 34,000 Btu/h |
18,000 to 40,000 Btu/h |
18,000 to 34,000 Btu/h |
18,000 to 40,000 Btu/h |
ENERGY STAR Qualified Unit | Yes | |||
SEER | 16.1 | 16.6 | 16.5 | 16.8 |
HSPF | 9.3 | 10.3 | 9.5 | 10.4 |
Compressor Type | Inverter (VCSi and H²i) | |||
i-see Sensor | Optional | Not Available | ||
Indoor Unit Noise (Low-Medium-High-Powerful) |
35-37-39-41 dB | 37=39-41-43 dB | 30-34-39 dB | 33-38-42 dB |
Outdoor Unit Noise (Cooling/Heating) |
52/53 dB | |||
Cooling Power Consumption | 2,480 W | 2,810 W | 2,500 W | 2,800 W |
Heating Power Consumption | 2,990 W | 3,270 W | 2,750 W | 3,150 W |
Power Supply | 240v, Split-Phase, 60Hz | |||
Moisture Removal | 3.9 l/h | 3.9 l/h | 4.2 l/h | 3.5 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | |||
Outdoor Temperatures for Heating (Min to Max) |
-25 to 21 °C |
PEA(D) Series Air Conditioners & Heat Pumps
The PEA(D) Series are available in cooling-only or heat-pump versions.
PEA(D) = Indoor ceiling-concealed evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).
Model | PEA-A12AA PUY-A12NHA4 |
PEA-A18AA PUY/Z-A18NHA4 |
PEAD-A24AA PUY/Z-A24NHA4 |
PEAD-A30AA PUY/Z-A30NHA4 |
Rated Cooling Capacity | 12,000 Btu/h [1 ton] |
18,000 Btu/h [1½ tons] |
24,000 Btu/h [2 tons] |
30,000 Btu/h [2½ tons] |
Cooling Capacity (Min to Max) |
6,000 to 12,000 Btu/h |
8,000 to 18,000 Btu/h |
12,000 to 24,000 Btu/h |
12,000 to 30,000 Btu/h |
Rated Heating Capacity * | N/A | 19,000 Btu/h [1½ tons] |
26,000 Btu/h [2¼ tons] |
32,000 Btu/h [2¾ tons] |
Heating Capacity * (Min to Max) |
N/A | 8,000 to 20,000 Btu/h |
12,000 to 28,000 Btu/h |
12,000 to 34,000 Btu/h |
ENERGY STAR Qualified Unit | No | Yes | No | Yes |
SEER | 13.8 | 14.3 | 16.0 | 15.5 |
HSPF | N/A | 10.0 | 10.2 | 9.4 |
Compressor Type | Inverter (VCSi) | |||
i-see Sensor | Not Available | |||
Indoor Unit Noise (Low-Medium-High) |
23-28-33 dB | 30-34-38 dB | 30-33-37 dB | 30-34-39 dB |
Outdoor Unit Noise (Cooling/Heating) |
46 dB | 46/47 dB | 48/50 dB | |
Cooling Power Consumption | 1,240 W | 2,150 W | 2,400 W | 3,850 W |
Heating Power Consumption | N/A | 1,540 W | 2,250 W | 2,990 W |
Power Supply | 240v, Split-Phase, 60Hz | |||
Moisture Removal | 1.2 l/h | 1.5 l/h | 3.3 l/h | 4.1 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | |||
Outdoor Temperatures for Heating (Min to Max) |
N/A | -12 to 21 °C |
Model | PEAD-A36AA PUY/Z-A36NHA4 |
PEAD-A42AA PUY/Z-A42NHA4 |
Rated Cooling Capacity | 34,200 Btu/h [2¾ tons] |
42,000 Btu/h [3½ tons] |
Cooling Capacity (Min to Max) |
12,000 to 35,000 Btu/h |
18,000 to 42,000 Btu/h |
Rated Heating Capacity * | 37,000 Btu/h [3 tons] |
45,000 Btu/h [3¾ tons] |
Heating Capacity * (Min to Max) |
12,000 to 38,000 Btu/h |
18,000 to 48,000 Btu/h |
ENERGY STAR Qualified Unit | Yes | No |
SEER | 15.0 | 13.8 |
HSPF | 9.8 | 10.0 |
Compressor Type | Inverter (VCSi) | |
i-see Sensor | Not Available | |
Indoor Unit Noise (Low-Medium-High) |
33-38-42 dB | 36-40-44 dB |
Outdoor Unit Noise (Cooling/Heating) |
48/50 dB | 51/55 dB |
Cooling Power Consumption | 4,850 W | 5,350 W |
Heating Power Consumption | 3,290 W | 3,820 W |
Power Supply | 240v, Split-Phase, 60Hz | |
Moisture Removal | 3.7 l/h | 4.3 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | |
Outdoor Temperatures for Heating (Min to Max) |
-12 to 21 °C |
* PUZ Series heat-pumps only.
PCA Series Air Conditioners & Heat Pumps
The PCA Series are available in cooling-only or heat-pump versions.
PCA = Indoor ceiling mounted evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).
Model | PCA-A24KA PUY/Z-A24NHA4 |
PCA-A30KA PUY/Z-A30NHA4 |
PCA-A36KA PUY/Z-A36NHA4 |
PCA-A42KA PUY/Z-A42NHA4 |
Rated Cooling Capacity | 24,000 Btu/h [2 tons] |
30,000 Btu/h [2½ tons] |
34,200 Btu/h [2¾ tons] |
42,000 Btu/h [3½ tons] |
Cooling Capacity (Min to Max) |
12,000 to 24,000 Btu/h |
12,000 to 30,000 Btu/h |
12,000 to 35,000 Btu/h |
18,000 to 42,000 Btu/h |
Rated Heating Capacity * | 26,000 Btu/h [2¼ tons] |
32,000 Btu/h [2¾ tons] |
37,000 Btu/h [3 tons] |
45,000 Btu/h [3¾ tons] |
Heating Capacity * (Min to Max) |
12,000 to 28,000 Btu/h |
12,000 to 34,000 Btu/h |
12,000 to 38,000 Btu/h |
18,000 to 48,000 Btu/h |
ENERGY STAR Qualified Unit | No | Yes | No | |
SEER | 16.8 | 14.5 | 14.4 | 15.8 |
HSPF | 10.9 | 9.2 | 10.2 | 10.2 |
Compressor Type | Inverter (VCSi) | |||
i-see Sensor | Not Available | |||
Indoor Unit Noise (Low-Medium1-Medium2-High) |
33-35-37-40 dB | 35-37-39-41 dB | 37-39-41-43 dB | 39-41-43-45 dB |
Outdoor Unit Noise (Cooling/Heating) |
48/50 dB | 51/55 dB | ||
Cooling Power Consumption | 2,340 W | 3,760 W | 4,630 W | 4,110 W |
Heating Power Consumption | 2,310 W | 3,210 W | 3,190 W | 3,830 W |
Power Supply | 240v, Split-Phase, 60Hz | |||
Moisture Removal | 2.7 l/h | 3.9 l/h | 4.0 l/h | 5.5 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | |||
Outdoor Temperatures for Heating (Min to Max) |
N/A | -12 to 21 °C |
* PUZ Series heat-pumps only.
PKA Series Air Conditioners & Heat Pumps
The PKA Series are available in cooling-only or heat-pump versions.
PKA = Indoor wall mounted evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).
Model | PKA-A12HA PUY-A12NHA4 |
PKA-A18HA PUY/Z-A18NHA4 |
PKA-A24HA PUY/Z-A24NHA4 |
PKA-A30KA PUY/Z-A30NHA4 |
PKA-A36KA PUY/Z-A436NHA4 |
Rated Cooling Capacity |
12,000 Btu/h [1 ton] |
18,000 Btu/h [1½ tons] |
24,000 Btu/h [2 tons] |
30,000 Btu/h [2½ tons] |
34,200 Btu/h [2¾ tons] |
Cooling Capacity (Min to Max) |
6,000 to 12,000 Btu/h |
8,000 to 18,000 Btu/h |
12,000 to 24,000 Btu/h |
12,000 to 30,000 Btu/h |
12,000 to 34,200 Btu/h |
Rated Heating Capacity * |
N/A | 19,000 Btu/h [1½ tons] |
26,000 Btu/h [2¼ tons] |
32,000 Btu/h [2¾ tons] |
37,000 Btu/h [3 tons] |
Heating Capacity * (Min to Max) |
N/A | 8,000 to 20,000 Btu/h |
12,000 to 28,000 Btu/h |
12,000 to 34,000 Btu/h |
12,000 to 38,000 Btu/h |
ENERGY STAR Qualified Unit |
No | Yes | |||
SEER | 15.2 | 15.3 | 17.0 | 15.5 | 14.0 |
HSPF | N/A | 9.5 | 10.8 | 8.9 | 9.3 |
Compressor Type | Inverter (VCSi) | ||||
i-see Sensor | Not Available | ||||
Indoor Unit Noise (Low-Medium-High) |
36-40-43 dB | 36-40-43 dB | 39-42-45 dB | 39-42-45 dB | 43-46-49 dB |
Outdoor Unit Noise (Cooling/Heating) |
46 dB | 46/47 dB | 48/50 dB | ||
Cooling Power Consumption |
1,190 W | 2,240 W | 2,270 W | 4,130 W | 5,030 W |
Heating Power Consumption |
N/A | 1,970 W | 2,330 W | 3,150 W | 3,610 W |
Power Supply | 240v, Split-Phase, 60Hz | ||||
Moisture Removal | 0.9 l/h | 2.5 l/h | 2.4 l/h | 3.8 l/h | 4.4 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | ||||
Outdoor Temperatures for Heating (Min to Max) |
N/A | -12 to 21 °C |
* PUZ Series heat-pumps only.
PLA Series Air Conditioners & Heat Pumps
The PLA Series are available in cooling-only or heat-pump versions.
PLA = Indoor 4-way ceiling cassette evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).
Model | PLA-A12BA PUY-A12NHA4 |
PLA-A18BA PUY/Z-A18NHA4 |
PLA-A24BA PUY/Z-A24NHA4 |
PLA-A30BA PUY/Z-A30NHA4 |
Rated Cooling Capacity | 12,000 Btu/h [1 ton] |
18,000 Btu/h [1½ tons] |
24,000 Btu/h [2 tons] |
30,000 Btu/h [2½ tons] |
Cooling Capacity (Min to Max) |
6,000 to 12,000 Btu/h |
8,000 to 18,000 Btu/h |
12,000 to 24,000 Btu/h |
12,000 to 30,000 Btu/h |
Rated Heating Capacity * | N/A | 19,000 Btu/h [1½ tons] |
26,000 Btu/h [2¼ tons] |
32,000 Btu/h [2¾ tons] |
Heating Capacity * (Min to Max) |
N/A | 8,000 to 20,000 Btu/h |
12,000 to 28,000 Btu/h |
12,000 to 34,000 Btu/h |
ENERGY STAR Qualified Unit | No | Yes | ||
SEER | 13.5 | 14.2 | 13.6 | |
HSPF | N/A | 9.8 | 8.5 | 8.7 |
Compressor Type | Inverter (VCSi) | |||
i-see Sensor | Optional | |||
Indoor Unit Noise (Low-Medium1-Medium2-High) |
27-28-29-31 dB | 28-29-31-32 dB | 28-30-32-34 dB | |
Outdoor Unit Noise (Cooling/Heating) |
46 dB | 46/47 dB | 48/50 dB | |
Cooling Power Consumption | 1,260 W | 1,940 W | 2,500 W | 4,100 W |
Heating Power Consumption | N/A | 1,900 W | 2,570 W | 3,370 W |
Power Supply | 240v, Split-Phase, 60Hz | |||
Moisture Removal | 0.8 l/h | 1.4 l/h | 2.4 l/h | 3.4 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-18 to 46 °C | -40 to 46 °C | ||
Outdoor Temperatures for Heating (Min to Max) |
N/A | -12 to 21 °C |
Model | PLA-A36AA PUY/Z-A36NHA4 |
PLA-A42AA PUY/Z-A42NHA4 |
Rated Cooling Capacity | 34,200 Btu/h [2¾ tons] |
42,000 Btu/h [3½ tons] |
Cooling Capacity (Min to Max) |
12,000 to 35,000 Btu/h |
18,000 to 42,000 Btu/h |
Rated Heating Capacity * | 37,000 Btu/h [3 tons] |
45,000 Btu/h [3¾ tons] |
Heating Capacity * (Min to Max) |
12,000 to 38,000 Btu/h |
18,000 to 48,000 Btu/h |
ENERGY STAR Qualified Unit | Yes | No |
SEER | 14.2 | 14.4 |
HSPF | 9.3 | |
Compressor Type | Inverter (VCSi) | |
i-see Sensor | Optional | |
Indoor Unit Noise (Low-Medium1-Medium2-High) |
32-34-37-40 dB | 34-36-39-41 dB |
Outdoor Unit Noise (Cooling/Heating) |
48/50 dB | 51/55 dB |
Cooling Power Consumption | 4,500 W | 4,600 W |
Heating Power Consumption | 3,300 W | 4,450 W |
Power Supply | 240v, Split-Phase, 60Hz | |
Moisture Removal | 3.8 l/h | 5.2 l/h |
Outdoor Temperatures for Cooling (Min to Max) |
-40 to 46 °C | |
Outdoor Temperatures for Heating (Min to Max) |
-12 to 21 °C |
* PUZ Series heat-pumps only.