Mitsubishi P-Series Mr.Slim

mitsubishi mrslim_pseries air conditioner by ductless.ca inc in toroto canada

Mitsubishi stylized photo

Ductless.ca, Inc. is an authorized Mitsubishi Mr. Slim dealer and has been serving the Toronto, Canada Area for over 25 years. Contact ductless.ca, Inc. for all of your ductless air conditioning and heating needs.

Mitsubishi Mr. Slim P-Series ductless air conditioners and heat pumps offer the attraction of being untraditional while providing efficiency and reliability for your commercial and industrial applications. Mitsubishi's Mr. Slim P-Series are powerful enough for the toughest situations such as offices, server rooms, equipment rooms, restaurants, elevator rooms and retail locations.
With the latest technology available, Mitsubishi Mr. Slim ductless units will provide you decades of reliable cooling while paying for itself in just a few years from the energy savings alone!
For smaller residential and commercial applications, please see our M-Series page.

Mitsubishi M-Series Ductless Features

Authorized Mitsubishi installer design

All Mitsubishi Mr. Slim ductless air conditioners sold through ductless.ca are authentic and not a grey market imports. All of our units are purchased from local distributors which in turn are supplied from Mitsubishi Electric Canada. You can take comfort in knowing that units purchased and installed by ductless.ca carry extended manufacturer warranties and support and are installed by factory trained professionals.


Canada flag

Mitsubishi P-Series ductless units are perfectly suited for the Canadian climate. Each unit comes standard with low-ambient cooling mode which allow the units to cool down to -18°C.
A special ultra low-ambient cooling option is also available for applications which require cooling when outside ambient temperatures dip down to -40°C (ultra-low ambient kit required).


Mitsubishi Hyper Heating design

Mitsubishi Electric's exclusive patent-pending Hyper-Heat Inverter (H2i™) technology delivers heat even when outdoor temperatures drop to -25°C! Levels that are unmatched with the competitors. H2i technology delivers 100% heating capacity when temperatures drop
down to -15°C and 80% heating capacity at -25°C.


VSCi Variable Speed Inverter compressors design

Most units have variable compressor speed inverter (VCSi) technology which adjusts the air conditioning capacity in response to demand. This allows Mitsubishi air conditioners to run more efficiently and reduce energy costs. By controlling the compressor rotation speed more precisely, VCSi technology provides high-speed cooling and heating with extra energy savings compared to conventional models.


Mitsubishi i-see Sensors design

Mitsubishi's i-see Sensors see more then just room temperature. Equally important factors for feeling comfortable include radiant temperature, air movements, humidity and more. The i-see sensors measure radiant hot and cold spots within the room and focus airflow into those spots. This revolutionary system also controls the air movement and humidity levels, producing a much more comfortable environment than ever before (option on PLA and PCA units only).


Mitsubishi wall mounted remote controller photo

The wall mounted slim smart remote control allows you to keep room comfort exactly where you want it and see the status of the entire system with just a glance such as temperature and airflow controls, enhanced service and maintenance functions, management security features and multiple systems control. Additionally, the display can be switched to one of eight different languages.


R410A refrigerant design

Mitsubishi has utilized R-410A which is a zero ozone depleting refrigerant since 2006 for all of their Mr. Slim ductless models in accordance with the Montreal Protocol.

PUZ Hyper Heat Series Heat Pumps

Example of Mitsubishi PUZ Hyper Heating Series Heat Pumps

Model PKA-A30KA PKA-A36KA PLA-A30BA PLA-A36BA
Rated Cooling Capacity 30,000 Btu/h
[2½ tons]
33,500 Btu/h
[2¾ tons]
30,000 Btu/h
[2½ tons]
34,000 Btu/h
[2¾ tons]
Cooling Capacity
(Min to Max)
18,000 to 30,000
Btu/h
18,000 to 34,200
Btu/h
18,000 to 30,000
Btu/h
18,000 to 36,000
Btu/h
Rated Heating Capacity 32,000 Btu/h
[2¾ tons]
38,000 Btu/h
[3¼ tons]
32,000 Btu/h
[2¾ tons]
38,000 Btu/h
[3¼ tons]
Heating Capacity
(Min to Max)
18,000 to 34,000
Btu/h
18,000 to 40,000
Btu/h
18,000 to 34,000
Btu/h
18,000 to 40,000
Btu/h
ENERGY STAR® Qualified Unit Yes
SEER 16.5 16.2 15.6 17.0
HSPF 9.5 10.0 9.4 10.0
Compressor Type Inverter (VCSi and H²i)
i-see Sensor Not Available Optional
Indoor Unit Noise
(Low-Medium-High-Powerful)
39-42-45 dB 43-46-49 dB 28-30-32-34 dB 32-34-37-40 dB
Outdoor Unit Noise
(Cooling/Heating)
52/53 dB
Cooling Power Consumption 2,500 W 2,790 W 2,450 W 2,690 W
Heating Power Consumption 2,930 W 3,410 W 3,440 W 3,230 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 3.8 l/h 4.1 l/h 3.4 l/h 3.3 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
-25 to 21 °C

Model PCA-A30KA PCA-A36KA PEAD-A30AA PEAD-A36AA
Rated Cooling Capacity 30,000 Btu/h
[2½ tons]
34,000 Btu/h
[2¾ tons]
30,000 Btu/h
[2½ tons]
34,000 Btu/h
[2¾ tons]
Cooling Capacity
(Min to Max)
18,000 to 30,000
Btu/h
18,000 to 36,000
Btu/h
18,000 to 30,000
Btu/h
18,000 to 36,000
Btu/h
Rated Heating Capacity 32,000 Btu/h
[2¾ tons]
38,000 Btu/h
[3¼ tons]
32,000 Btu/h
[2¾ tons]
38,000 Btu/h
[3¼ tons]
Heating Capacity
(Min to Max)
18,000 to 34,000
Btu/h
18,000 to 40,000
Btu/h
18,000 to 34,000
Btu/h
18,000 to 40,000
Btu/h
ENERGY STAR Qualified Unit Yes
SEER 16.1 16.6 16.5 16.8
HSPF 9.3 10.3 9.5 10.4
Compressor Type Inverter (VCSi and H²i)
i-see Sensor Optional Not Available
Indoor Unit Noise
(Low-Medium-High-Powerful)
35-37-39-41 dB 37=39-41-43 dB 30-34-39 dB 33-38-42 dB
Outdoor Unit Noise
(Cooling/Heating)
52/53 dB
Cooling Power Consumption 2,480 W 2,810 W 2,500 W 2,800 W
Heating Power Consumption 2,990 W 3,270 W 2,750 W 3,150 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 3.9 l/h 3.9 l/h 4.2 l/h 3.5 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
-25 to 21 °C

PEA(D) Series Air Conditioners & Heat Pumps

Example of Mitsubishi PEA(D) Series Air Conditioners and Heat Pumps

The PEA(D) Series are available in cooling-only or heat-pump versions.
PEA(D) = Indoor ceiling-concealed evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).

Model PEA-A12AA
PUY-A12NHA4
PEA-A18AA
PUY/Z-A18NHA4
PEAD-A24AA
PUY/Z-A24NHA4
PEAD-A30AA
PUY/Z-A30NHA4
Rated Cooling Capacity 12,000 Btu/h
[1 ton]
18,000 Btu/h
[1½ tons]
24,000 Btu/h
[2 tons]
30,000 Btu/h
[2½ tons]
Cooling Capacity
(Min to Max)
6,000 to 12,000
Btu/h
8,000 to 18,000
Btu/h
12,000 to 24,000
Btu/h
12,000 to 30,000
Btu/h
Rated Heating Capacity * N/A 19,000 Btu/h
[1½ tons]
26,000 Btu/h
[2¼ tons]
32,000 Btu/h
[2¾ tons]
Heating Capacity *
(Min to Max)
N/A 8,000 to 20,000
Btu/h
12,000 to 28,000
Btu/h
12,000 to 34,000
Btu/h
ENERGY STAR Qualified Unit No Yes No Yes
SEER 13.8 14.3 16.0 15.5
HSPF N/A 10.0 10.2 9.4
Compressor Type Inverter (VCSi)
i-see Sensor Not Available
Indoor Unit Noise
(Low-Medium-High)
23-28-33 dB 30-34-38 dB 30-33-37 dB 30-34-39 dB
Outdoor Unit Noise
(Cooling/Heating)
46 dB 46/47 dB 48/50 dB
Cooling Power Consumption 1,240 W 2,150 W 2,400 W 3,850 W
Heating Power Consumption N/A 1,540 W 2,250 W 2,990 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 1.2 l/h 1.5 l/h 3.3 l/h 4.1 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
N/A -12 to 21 °C

Model PEAD-A36AA
PUY/Z-A36NHA4
PEAD-A42AA
PUY/Z-A42NHA4
Rated Cooling Capacity 34,200 Btu/h
[2¾ tons]
42,000 Btu/h
[3½ tons]
Cooling Capacity
(Min to Max)
12,000 to 35,000
Btu/h
18,000 to 42,000
Btu/h
Rated Heating Capacity * 37,000 Btu/h
[3 tons]
45,000 Btu/h
[3¾ tons]
Heating Capacity *
(Min to Max)
12,000 to 38,000
Btu/h
18,000 to 48,000
Btu/h
ENERGY STAR Qualified Unit Yes No
SEER 15.0 13.8
HSPF 9.8 10.0
Compressor Type Inverter (VCSi)
i-see Sensor Not Available
Indoor Unit Noise
(Low-Medium-High)
33-38-42 dB 36-40-44 dB
Outdoor Unit Noise
(Cooling/Heating)
48/50 dB 51/55 dB
Cooling Power Consumption 4,850 W 5,350 W
Heating Power Consumption 3,290 W 3,820 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 3.7 l/h 4.3 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
-12 to 21 °C

* PUZ Series heat-pumps only.

PCA Series Air Conditioners & Heat Pumps

Examples of Mitsubishi PCA Series Air Conditioners and Heat Pumps

The PCA Series are available in cooling-only or heat-pump versions.
PCA = Indoor ceiling mounted evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).

Model PCA-A24KA
PUY/Z-A24NHA4
PCA-A30KA
PUY/Z-A30NHA4
PCA-A36KA
PUY/Z-A36NHA4
PCA-A42KA
PUY/Z-A42NHA4
Rated Cooling Capacity 24,000 Btu/h
[2 tons]
30,000 Btu/h
[2½ tons]
34,200 Btu/h
[2¾ tons]
42,000 Btu/h
[3½ tons]
Cooling Capacity
(Min to Max)
12,000 to 24,000
Btu/h
12,000 to 30,000
Btu/h
12,000 to 35,000
Btu/h
18,000 to 42,000
Btu/h
Rated Heating Capacity * 26,000 Btu/h
[2¼ tons]
32,000 Btu/h
[2¾ tons]
37,000 Btu/h
[3 tons]
45,000 Btu/h
[3¾ tons]
Heating Capacity *
(Min to Max)
12,000 to 28,000
Btu/h
12,000 to 34,000
Btu/h
12,000 to 38,000
Btu/h
18,000 to 48,000
Btu/h
ENERGY STAR Qualified Unit No Yes No
SEER 16.8 14.5 14.4 15.8
HSPF 10.9 9.2 10.2 10.2
Compressor Type Inverter (VCSi)
i-see Sensor Not Available
Indoor Unit Noise
(Low-Medium1-Medium2-High)
33-35-37-40 dB 35-37-39-41 dB 37-39-41-43 dB 39-41-43-45 dB
Outdoor Unit Noise
(Cooling/Heating)
48/50 dB 51/55 dB
Cooling Power Consumption 2,340 W 3,760 W 4,630 W 4,110 W
Heating Power Consumption 2,310 W 3,210 W 3,190 W 3,830 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 2.7 l/h 3.9 l/h 4.0 l/h 5.5 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
N/A -12 to 21 °C

* PUZ Series heat-pumps only.

PKA Series Air Conditioners & Heat Pumps

Example of Mitsubishi PKA Series Air Conditioners and Heat Pumps

The PKA Series are available in cooling-only or heat-pump versions.
PKA = Indoor wall mounted evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).

Model PKA-A12HA
PUY-A12NHA4
PKA-A18HA
PUY/Z-A18NHA4
PKA-A24HA
PUY/Z-A24NHA4
PKA-A30KA
PUY/Z-A30NHA4
PKA-A36KA
PUY/Z-A436NHA4
Rated
Cooling Capacity
12,000 Btu/h
[1 ton]
18,000 Btu/h
[1½ tons]
24,000 Btu/h
[2 tons]
30,000 Btu/h
[2½ tons]
34,200 Btu/h
[2¾ tons]
Cooling Capacity
(Min to Max)
6,000 to 12,000
Btu/h
8,000 to 18,000
Btu/h
12,000 to 24,000
Btu/h
12,000 to 30,000
Btu/h
12,000 to 34,200
Btu/h
Rated
Heating Capacity *
N/A 19,000 Btu/h
[1½ tons]
26,000 Btu/h
[2¼ tons]
32,000 Btu/h
[2¾ tons]
37,000 Btu/h
[3 tons]
Heating Capacity *
(Min to Max)
N/A 8,000 to 20,000
Btu/h
12,000 to 28,000
Btu/h
12,000 to 34,000
Btu/h
12,000 to 38,000
Btu/h
ENERGY STAR
Qualified Unit
No Yes
SEER 15.2 15.3 17.0 15.5 14.0
HSPF N/A 9.5 10.8 8.9 9.3
Compressor Type Inverter (VCSi)
i-see Sensor Not Available
Indoor Unit Noise
(Low-Medium-High)
36-40-43 dB 36-40-43 dB 39-42-45 dB 39-42-45 dB 43-46-49 dB
Outdoor Unit Noise
(Cooling/Heating)
46 dB 46/47 dB 48/50 dB
Cooling
Power Consumption
1,190 W 2,240 W 2,270 W 4,130 W 5,030 W
Heating
Power Consumption
N/A 1,970 W 2,330 W 3,150 W 3,610 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 0.9 l/h 2.5 l/h 2.4 l/h 3.8 l/h 4.4 l/h
Outdoor Temperatures
for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures
for Heating
(Min to Max)
N/A -12 to 21 °C

* PUZ Series heat-pumps only.

PLA Series Air Conditioners & Heat Pumps

Examples of Mitsubishi PLA Series Air Conditioners and Heat Pumps

The PLA Series are available in cooling-only or heat-pump versions.
PLA = Indoor 4-way ceiling cassette evaporator units.
PUY = Outdoor condenser units (cooling only).
PUZ = Outdoor condenser units (cooling and heating).

Model PLA-A12BA
PUY-A12NHA4
PLA-A18BA
PUY/Z-A18NHA4
PLA-A24BA
PUY/Z-A24NHA4
PLA-A30BA
PUY/Z-A30NHA4
Rated Cooling Capacity 12,000 Btu/h
[1 ton]
18,000 Btu/h
[1½ tons]
24,000 Btu/h
[2 tons]
30,000 Btu/h
[2½ tons]
Cooling Capacity
(Min to Max)
6,000 to 12,000
Btu/h
8,000 to 18,000
Btu/h
12,000 to 24,000
Btu/h
12,000 to 30,000
Btu/h
Rated Heating Capacity * N/A 19,000 Btu/h
[1½ tons]
26,000 Btu/h
[2¼ tons]
32,000 Btu/h
[2¾ tons]
Heating Capacity *
(Min to Max)
N/A 8,000 to 20,000
Btu/h
12,000 to 28,000
Btu/h
12,000 to 34,000
Btu/h
ENERGY STAR Qualified Unit No Yes
SEER 13.5 14.2 13.6
HSPF N/A 9.8 8.5 8.7
Compressor Type Inverter (VCSi)
i-see Sensor Optional
Indoor Unit Noise
(Low-Medium1-Medium2-High)
27-28-29-31 dB 28-29-31-32 dB 28-30-32-34 dB
Outdoor Unit Noise
(Cooling/Heating)
46 dB 46/47 dB 48/50 dB
Cooling Power Consumption 1,260 W 1,940 W 2,500 W 4,100 W
Heating Power Consumption N/A 1,900 W 2,570 W 3,370 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 0.8 l/h 1.4 l/h 2.4 l/h 3.4 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-18 to 46 °C -40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
N/A -12 to 21 °C

Model PLA-A36AA
PUY/Z-A36NHA4
PLA-A42AA
PUY/Z-A42NHA4
Rated Cooling Capacity 34,200 Btu/h
[2¾ tons]
42,000 Btu/h
[3½ tons]
Cooling Capacity
(Min to Max)
12,000 to 35,000
Btu/h
18,000 to 42,000
Btu/h
Rated Heating Capacity * 37,000 Btu/h
[3 tons]
45,000 Btu/h
[3¾ tons]
Heating Capacity *
(Min to Max)
12,000 to 38,000
Btu/h
18,000 to 48,000
Btu/h
ENERGY STAR Qualified Unit Yes No
SEER 14.2 14.4
HSPF 9.3
Compressor Type Inverter (VCSi)
i-see Sensor Optional
Indoor Unit Noise
(Low-Medium1-Medium2-High)
32-34-37-40 dB 34-36-39-41 dB
Outdoor Unit Noise
(Cooling/Heating)
48/50 dB 51/55 dB
Cooling Power Consumption 4,500 W 4,600 W
Heating Power Consumption 3,300 W 4,450 W
Power Supply 240v, Split-Phase, 60Hz
Moisture Removal 3.8 l/h 5.2 l/h
Outdoor Temperatures for Cooling
(Min to Max)
-40 to 46 °C
Outdoor Temperatures for Heating
(Min to Max)
-12 to 21 °C

* PUZ Series heat-pumps only.

Want to Buy, Install, or Service a Mitsubishi Mr.Slim Unit?

Ductless.ca has been serving the Greater Toronto Area for over 25 years. Whether you need sales, service or installation of a Mitsubishi P-Series Mr.Slim unit, we would be glad to help you.

Installation

Documentation

Mitsubishi Electric Warranty

Mitsubishi 7 Year Compressor Warranty Mitsubishi 2 Year Parts Warranty Mitsubishi 2 Year Labour Warranty

mitsubishi minus_40_cooling in toronto by ductless.ca

External Links

Canadian Efficiency Ratings

Canada Energuide logo

13.5 - 17.0
Seasonal Energy Efficiency Rating (SEER) for available Mitsubishi P-Series units

mits_faq

mitsubishi interactive remote for ductless heat pump ac

Free AC line-set covers from ductless.ca

Start Up Services for ductless ac and boilers

Buy European Radiator Humidifiers in Canada online

5 free Radiator Humidifiers with every boiler & heat pump installed by  ductless.ca

Testimonials